RMLD-IS® | RMLD Intrinsically Safe
RMLD-IS® | RMLD Intrinsically Safe
|
Description |
Our intrinsically safe Remote Methane Leak Detector (RMLD-IS) is an eye-safe laser-based natural gas detector (methane) that can quickly and efficiently detect leaks up to one hundred feet away allowing remote detection of difficult to access places such as; busy roadways, locked yards, underground piping, compressor stations, offshore platforms, plant/industrial inspections, gas processing plants, gas gathering, drilling sites, landfills, difficult terrains and more. When the infrared laser beam is transmitted from the launch port, some of the laser light is reflected back and converted to an electrical signal that carries the information needed to deduce the methane concentration. The RMLD-IS has proven to be a highly effective leak survey instrument, compared to flame ionization and similar equipment, but with the added advantage of remote detection. By design the RMLD-IS is capable of achieving significant productivity gains and drastically reduce operations and maintenance costs.
The RMLD-IS is also a game-changer in the environmental industry. The proof is in the numbers with thousands of units in use worldwide. The RMLD-IS’ remote detection allows users to satisfy increasing restrictions on air quality controls and increase success in reducing emissions from underground pipeline networks as well as above ground fugitive sources. |
Specifications |
Detection Method: Tunable Diode Laser Absorption Spectroscopy (TDLAS) Measurement Range: 0 to 99,999 ppm-m Sensitivity: 5 ppm-m at distances from 0 to 50 ft (15 m) 10 ppm-m or better at distances from 50 to 100 ft (15 to 30 m) Intrinsic Safety: Class 1 Division 1 Group D, T4 in accordance with UL 913 & CSA C22.2 No 157, MetLab Listing #E112840 Detection Distance: 100 ft (30 m) nominal. Actual distance may vary due to background type and conditions. Beam Size: Conical in shape with a 22” diameter at 100 ft (56 cm at 30 m) Detection Alarms Modes: Digital Methane Detection (DMD): Audible tone relative to concentration when detection threshold exceeded Adjustable Detection Alarm Level from 0 to 255 ppm-m Pure Tone: Continuous audio tone relative to concentration Adjustable V olume: 8 Levels System Fault Warning: Unique audible tone and indication on the display Self Test & Calibration: Built-in Self Test and Calibration function verifies operation and adjusts laser wavelength for maximum sensitivity. Test gas cell integrated within carrying case. Compliance: EMC (EN61000-6-2, EN6100-6-4) Laser Eye Safety: IR Laser: Class I (CDRH, ANSI and IEC) Green Spotter Laser: Class IIIa; Do not stare into beam or view directly with optical instruments Communications: RS232 and Bluetooth Standard Display: Large, easy to read backlit LCD (.75” Numeric) Operating Temperature: 0° to + 122° F (-17° to 50° C) Humidity: 5 to 95% RH, non-condensing Enclosure: IP54 (Water splash and Dust resistant) Instrument Weight: 10 lbs (Transceiver 3 lbs, Controller 7 lbs); (4.5 kg; 1.3 kg, 3.2 kg) Carry Case: 14 lbs; 34” x 9 ½” x 14” (6.4 kg; 86 cm x 24 cm x 36 cm) Battery: Internal, rechargeable, Li ion battery pack, 11.1 Vdc Battery Run Time: 8 hours at 32° F without backlight on, minimum Battery Charging: External, in-line, 110-240 Vac, 50 / 60 hertz, international, 19 Vdc power supply Charge Time, Maximum: 8 hours Charging Indicator: Integrated into controller panel Shoulder Strap: Single over the shoulder padded strap with Ergonomic dual strap and belt system
|
Technical Library |