RMLD-FR™ | RMLD First Responder


RMLD-FR™ | RMLD First Responder 

 Description
The RMLD – First Responder (RMLD-FR™), allows for the rapid scan of standard venting points inside a structure from a safe distance to establish the presence of methane gas by first responder and fire service personnel. The instrument is based on Heath Consultants’ popular RMLD legacy and RMLD-CS™ designs with many of the same functionality and features as the RMLD-CS version but with a streamlined user interface.

Most often, first responders/fire service are called to address fire and major natural gas emergencies, using equipment that places them too close to possibly harmful structures.

The remote detection of the RMLD-FR enables the operator to shine the beam through most windows, providing them a visual and audible signal regarding the presence of methane gas. This rapid scan allows first responders to make quick decisions and establish control of the gas and ignition sources if a detection is present.

 Specifications

General 

RMLD-FR Weight:                                       3 lbs (approx
Carry Case Dimensions:                               21” x 17.5” x 9.5
Storage:                                                  Internal SD card (not removable)


Power           

Battery:                                                   Removable, rechargeable Lithium-ion pack, 10.8 VDC 3.2Ah
Battery Run Time:                                       8 hours at 32° F (approx.)
Battery Charger:                                         External 110-240 VAC, 50/60 Hz Universal  
Charge Time:                                             2-3 hours full charge (approx.)
Charging Indicator:                                      Integrated into Dual Battery Charger                                       


Detection Method/Measurement System 

Detection Distance:                                     100 ft (30m) nominal - may vary due to background type and conditions  
Measurement Range:                                   0 to 50K PPM-M
Sensitivity:                                               5 PPM-M at distances from 0 to 100 ft (30m)
Beam Size:                                               Conical in shape with a 22” diameter at 100 ft (55cm at 30m)


Display:                                                   3.5” color LCD / 320x240

Color Camera:                                           Aperture f/2.6 / FOV 94DEG (at 6.0mm image circle)


Lasers 

IR Laser:                                                  Class I
Spotter Laser:                                           On time duration is 2 minutes Class 2 (II) <2mW @532nm                                                                                                          Spot size is 7mm at 15M Complies with 21 CFR 1040.10 and 1040.11 except for deviations                                                                    pursuant to Laser Notice No. 50, dated June 24, 2007

Eye Safety Warning:                                    Do not stare into beam or view directly with optical instrument 
Avertissement de sécurité des yeux:               Ne jamais fixer le faisceau ni le regarder directement avec des instruments optiques.


GPS 

Compatible With GPS:                                 GLONASS Beidou Galilieo

Communication:                                        Bluetooth 4.2 BLE (to support future features and mobile applications)

                                                            WiFi USB Dual Mode USB Port Max Rating UM = 5V, IN = A 


Alarms

Digital Methane Detection (DMD):                   Audible tone and visible color border when detection threshold exceeded 
Adjustable Detection Alarm Level 50’ / 100’:     1 to 200 PPM M / 1 to 400 PPM M
System Fault & Warnings:                            Audible alarm and visual indication on the display


Data Logging  

Saves to Internal Memory:                           FAULT logs / Self-Test logs / Captures
Data Collected:Includes, but not limited to:       CH4 PPM-M measurement GPS location Timestamp Battery level / Battery voltage                                                                           Serial number of the instrument


Operating Conditions 

Operating Temperature:                              0° to +122° F (-17° to 50° C)
Humidity:                                               5 to 95% RH, non-condensing
Altitude:                                                 Up to 6560 ft (2000 m)
Environment of Use:                                  Pollution degree 2 or better Outdoor use


Regulatory 

Instrument Protection:                                IP54 (water splash and dust resistant)
Compliance:                                             EMC (EN61000-6-2, EN6100-6-4)
Low Voltage Directive:                                (2014/35/EU)
Radio Equipment Directive:                          (2014/53/EU)


ETSI EN 301 489-1 v2.2.0
EN 61326-1:2013
47 CFR Part 15 & ICES-003