ODORATOR 2™ | Odor Intensity Test Instrument
ODORATOR 2™ | Odor Intensity Test Instrument |
Description |
The Heath ODORATOR 2 is an odorization survey audit system or odor intensity test instrument that with proper use fulfills D.O.T.Code 192.625 requirements. This state-of-the-art, portable, electronic, GNSS based audit system is an ideal tool for customer service personnel and other individuals determining odor intensity levels within a gas distribution or transmission systems.
|
Specifications |
Available Models: Methane, 1.00% and 0.50% “Massachusetts”, 0.15%Propane, 0.44% Battery Pack Run-Time: 3 weeks, typical Connectivity: USB 2.0 and Bluetooth Recording Media: SDHC memory card; not accessible Recorded Data: All readings with GNSS location, UTC time and date, instrument status and breadcrumb trail Inlet Supply Pressure: 7” water column, typical / 4 p.s.i.g. maximum Size: 14 x 12 x 5” (35 x 30 x 8 cm) Weight: 9.5 lbs (4.3 kg) Temperature Range: **0°F to 122°F (-18 to 50°C) Elevation Range: Sea level to 10,000 ft. (3,048 meters) Compliance: GPTC (49 CFR Part 192 Subpart L 192.625), ASTM D6273 EMI/EMC: US: FCC 47 CFR Part 15 Subpart B Canada: Industry Canada ICES-003; Class A European Union: EMC Directive 2004/108/EC utilizing EN 61326- 1:2006 for Portable Test Measurement Equipment Supplied with NRTL Listed cUL/ UL / CE marked power supply |