ET500 Series


   Description

 

ET501 industrial style push-in RTD assemblies with terminal head are designed for measuring temperatures in liquids and gases.

Applications include HVAC and refrigeration, heating installations, ovens, furnaces and plant engineering, as well as industrial automation.

Depending on the application needs, platinum RTD elements with specific nominal resistance and accuracy class for temperatures up to +500 °C, common thermistors, protection tubes of different size, various terminal heads, process connection fittings and outputs can be ordered.

Features

  • For temperature measurement -50...+500 °C
  • Pt100 Class A or custom sensing element
  • A4 / AISI316L stainless steel protection tube
  • DIN Form B or custom terminal head
  • Output 4-20 mA / 0-10 V or RS485 Modbus RTU

 

   Technical Data

 


 

   Description

 

ET521 screw-in RTD thermometers with terminal head and replaceable measuring insert are designed for measuring temperatures in liquids and gases under demanding conditions.

Applications include heating installations, ovens, furnaces and plant engineering, as well as industrial automation.

The protection tube with welded screw fitting functions as an integrated thermowell and the measuring insert can be replaced without interrupting the process.

The standard version includes Pt100 class A sensing element with measurement range -50...+250 °C, process connection with G1/2B thread and DIN B type terminal head.

Features

  • For temperature measurement -50...+500 °C
  • Pt100 Class A or custom sensing element
  • A4 / AISI316L acid proof steel protection tube
  • Integrated thermowell with threaded connection
  • 4-20 mA / 0-10 V analog or RS485 Modbus RTU digital
 
   Technical Data

 


 

   Description

 

ET511 series industrial style screw-in RTD assemblies with terminal head are designed for measuring temperatures in liquids and gases.

Applications include HVAC and refrigeration, heating installations, ovens, furnaces and plant engineering, as well as industrial automation.

The standard version includes Pt100 class A sensing element with measurement range -50...+250 °C, process connection with G1/2" thread and DIN B type terminal head.

Depending on the application needs, many features can be supplied: platinum RTD sensing elements with specific nominal resistance and accuracy class for temperatures up to +500 °C or common thermistors, protection tubes of different size, various terminal heads, process connection fittings and outputs.

 

Features

  • For temperature measurement -50...+500 °C
  • Pt100 Class A or custom sensing element
  • A4 / AISI316L acid-proof steel protection tube
  • G1/2 or custom threaded process connection
  • 4-20 mA / 0-10 V analog or RS485 Modbus RTU digital"
 
   Technical Data

 

Visitors: 207,308