General Weight: 3 lbs (approx.) Carry Case Dimensions: 21” x 17.5” x 9.5” Display: 3.5” color LCD, 320 x 240 resolution
Power Battery: Removable Rechargeable Lithium-ion pack, 10.8 VDC at 3.2Ah Battery Run Time: 8 hours at 32° F (approx.) Battery Charger: External, 110-240 VAC, 50/60 Hz Universal Dual Bay, Delivers 12W at 25°C per battery Charge Time: 2-3 hours full charge (approx.)
Detection/Measurement System Detection Method: Tunable Diode Laser Absorption Spectroscopy (TDLAS) Detection Distance: 100 ft (30m) nominal - may vary due to background type and conditions Measurement Range: 0 to 50K PPM-M Sensitivity: 5 PPM-M at distances from 0 to 100 ft (30m) Beam Size: Conical in shape with a 22” diameter at 100 ft (55cm at 30m)
Lasers IR Laser: Class I Green Spotter: Class 2(II) <5mW @ 510-530 nm Spot size is 7mm at 15M Complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser / Notice No. 50, dated June 24, 2007 Laser Eye Safety Warning: Do not stare into beam or view directly with optical instrument
GNSS Compatibility: GPS GLONASS Beidou Galilieo
Communication: USB Dual Mode – flash drive and communications USB Port Max Rating: Um = 5V, In = 5 A Bluetooth 4.2 BLE WiFi b/g
Alarms Digital Methane Detection (DMD): Audible tone and visual alerts when detection threshold exceeded Adjustable Detection Alarm Level: 1 to 999 PPM-M Alarm Response Time: Typically 0.1 - 0.2 seconds Real Time (RT): Continuous beep rate relative to concentration from 10-1000 PPM-M System Fault & Warnings: Audible alarm and visual indication on the display
Testing Built-In Self-Test: Verifies operation and adjusts laser wavelength for maximum sensitivity Test Gas Cell: Integrated within carrying case
Operating Conditions Operating Temperature: 0° to +122° F (-17° to 50° C) Humidity: 5 to 95% RH, non-condensing Altitude: Up to 2000M Environment of Use: Pollution degree 2 or better Outdoor use
Regulatory Ingress Protection: IP54 (water splash and dust resistant) Compliance: EMC (EN61000-6-2, EN6100-6-4) Low Voltage Directive: (2014/35/EU) Radio Equipment Directive: (2014/53/EU) ETSI EN 301 489-1 v2.2.0 EN 61326-1:2013 47 CFR Part 15 & ICES-003
Ordinary Location Safety: UL 61010-1 CAN/CSA-C22.2 No 61010-1-12
Hazardous Location Safety: Class I, Zone 2, AEx ic op is IIA T4 Gc Class I, Division 2, Group D Intrinsically Safe
|