DP-IR+™ | Detecto Pak-Infrared+

DP-IR+™ | Detecto Pak-Infrared+
 Description
The DP-IR+ is the latest generation of leak survey instruments from Heath that will greatly improve the productivity 
and safety of a walking/ mobile survey because of high sensitivity and fast response. It is an extremely sensitive,
advanced leak detector capable of detecting methane without false alarming on other gases. The DP-IR+ operates
under a variety of environmental conditions including cold or hot weather. Its rugged design will stand up to normal
field use and operating conditions.
The new DP-IR+ Application “App” provides an easy way for users to connect to Heath DP-IR+ devices via Bluetooth 
Low Energy (BLE) and capture survey data. Available for both iOS and Android platforms.
 Specifications
Detection Method:					Infrared Controlled Interference
							Polarization Spectrometer

Measurement Range:				0 to 10,000 PPM; 1 to 100% Gas

Display Range:					Auto Ranging PPM: 0-10,000 %Gas: 1-100%
							Manual Ranging PPM scale: 0-10,000 %Gas scale: 0-100%

Sensitivity:						1 PPM

Resolution:						0-1000 PPM: 1 PPM
							1000-10,000 PPM: 5 PPM
							1-100%Gas: 0.1%

Accuracy:						Greater of ±0.5% or ±10% of reading (normal temperature and pressure, 
							% gas on manual mode)

Response Time:*					PPM Mode: T10< 0.7s, T50< 1.3s
							PPM Mode with Survey Probe: T10< 1.2s, T50< 1.8s
							%Gas Mode with Method 21 Probe: T50< 1.8s, T90< 2.5s; 
							Recovery Time T10< 2.0s

Sample Flow Rate:*					2.0 LPM (with Survey Probe attached)

Connectivity:*					Bluetooth 5 Low Energy (BLE) (compatible with iOS, Android and 
							Windows devices)

Detection Alarms
Modes:						Digital Methane Detection (DMD):
							Audible tone when detection threshold exceeded. Adjustable Alarm 
							Level from 1 to 9,000 PPM
							Tick: Continuous audio tone relative to concentration

System Fault Warning:				Audible tone and indication on the display

Self Test & Calibration:				Built in Self Test and Calibration function verifies operation and 
							adjusts calibration for maximum sensitivity. Test gas cell 
							integrated within the instrument.

Compliance:						EN 61326-1
							Conducted Emissions Class B	EN 61326-1
							Radiated Emissions Class B	EN 61000-4-2 4kV/8kV
							ANSI C63.4 Class B			EN 61000-4-3 3 V/M
							FCC 47 CFR Part 15 Class B

Dust Filter:						Replaceable filter provides dust protection. Easy change-out quick 
							disconnect filter cap.

Display:						Large easy to read backlit LCD (0.75” Numeric)

Operating Temperature:				0 to + 122 F (-17 to 50 C) (nominal battery voltage)

Humidity:						5 to 95% RH, non-condensing

Enclosure:						IP54 (Water splash and Dust resistant)

Instrument Weight:					5.6 lbs.

Carry Case:						13 lbs empty; 21 lbs filled 24.5” x 21” x 9”

Power Supply:					Internal rechargeable Li-ion battery or External 12 Vdc car battery 
							with power conditioner

Battery Operating Life:				8 hours at 32º F without backlight on

Battery Charger:					External, in-line, 110 - 240 VAC, 50 / 60 hertz. 10 hours to 90% charge

Shoulder Strap:					Single over the shoulder padded strap

Alarm Volume:					108 dBs @ Alarm port (A-fast)

Survey Probe:					Quick connect fitting with locking clasp. Adjustable length 
							from 25” to 41”

Bar hole Probe:					Std: 20”; Optional 36”

Method 21 Probe (optional):			Std: 5’, with quick connect fitting and locking clasp

Intrinsic Safety:					Class I Division I Group D T3
							UL 913, CSA 22.2 No. 157, MET Labs #E112840

* These features only available on DP-IR+ released January 2020 onwards.
 Technical Library