Refrigerants Detected All CFC, HFC and HCFC refrigerants, including but not limited to: R-12, R-22, R-134a, R-404A, R-502, R-507, HFO-1233zd, HFO-1234yf and HFO-1234ze
Combustible Gases Detected All hydrocarbons/combustible gases, including but not limited to: methane (CH4), propane (C3H8), hydrogen (H2), butane (C4H10) and pentane (C5H12)
Sensitivity Refrigerants: 0.5 oz/yr (14 g/yr) for R-12 and R-134a per SAE J1627 0.1 oz/yr (3 g/yr) when held at leak source for approx. 5 seconds Combustibles: 50 ppm CH4 (minimum)
Response Time Instantaneous
Leak Indicators Dual LED scales, LED in probe tip and internal speaker (w/mute option)
Automatic Background Adjustment Yes
Power 4x AA batteries
Run Time 4-5 hours typical (alkaline batteries)
Size (H x W x D) 1.75 x 9.62 x 2.25 in. (4.5 x 24.4 x 5.7 cm)
Weight 0.86 lb. (0.39 kg) including batteries
Sensor Life Refrigerant: 1 year (typical) Combustible: 5 years (typical)
Operating Conditions 32 to 122 °F (0 to 50 °C), 10 to 90% RH (non-condensing), 1 ATM
Warm-up Time 10 seconds
Approvals CE mark SAE J1627 (refrigerant sensor only) UL 913 Class 1, Division 1, Group D (combustible sensor only)
Warranty 1 year (including sensors)
|