PCA 3
PCA®3
- Measures up to 4 gases simultaneously (minimum O2 and CO), including NOx using NO only or NO + NO2
- Exclusive B-Smart® pre-calibrated sensors for easy field replacement or upgrades
- 3.5 inch color LCD with customizable layout and zoom for viewing the readings you want to see
- Ten standard fuels with option to add up to 2 additional fuels to the library
Description
The PCA®3 is the perfect tool for busy technicians and boiler contractors who need to ensure safe operating conditions, determine combustion efficiency and perform emissions testing. Up to 4 sensors can be installed, measuring all gases simultaneously, including NOx (calculated from NO or measured from NO + NO2). Sensors can be added in the field without down time or replaced using B-Smart® pre-calibrated sensors. The PCA®3 calculates values like efficiency, CO2 and CO air-free to help monitor combustion processes effectively and accurately.
The PCA®3 is designed for on-demand or semi-continuous sampling of light industrial, institutional, commercial and residential furnaces, boilers and appliances. It complies with regulations such as U.S. EPA test methods, EN 50379, CTM-030 and state/local protocols including SCAQMD. With sturdy metal gas and draft connectors, rugged construction, simple operation and quick, cost-effective maintenance, the PCA®3 is the workhorse of the industry.
*Note: The PCA®3 calculates CO2 value based upon other measured values during the combustion process. It does not measure CO2 directly.
Specifications
Measurements: O2 CO (low-range, H2-compensated) CO (high-range, optional) NO (optional) NO2 (optional) SO2 (optional) Stack temperature Primary/ambient air temperature Draft/differential pressure |
0 to 20.9% 0 to 4000 ppm 4001 to 20,000 ppm 0 to 3000 ppm 0 to 500 ppm 0 to 5000 ppm -4 to 2192 °F (-20 to 1200 °C) -4 to 999 °F (-20 to 537 °C) ± 72 inH2O (± 179 mbar) |
Display |
3.5 in. color LCD w/backlight |
Power |
4x AA batteries or optional wall adapter |
Run Time |
10 hours minimum (alkaline batteries) |
Size (H x W x D) |
9.0 x 3.0 x 2.5 in. (22.9 x 7.6 x 6.3 cm) |
Weight |
2.4 lb. (1.1 kg) including batteries and probe |
Fuels[1] |
Natural gas, coal, oil 2/4/6, wood, kerosene, bagasse, propane, butane, LPG, digester gas, KOKS, LEG, biofuel, +2 optional custom fuels |
Operating Conditions |
Analyzer: 32 to 104 °F (0 to 40 °C), 15 to 90% RH (non-condensing), 1 ATM ± 10% Probe tip[2]: 1000 °F (538 °C) maximum, 10 inH2O (25 mbar) maximum draft |
Warm-up Time |
60 seconds |
Memory |
1000 locations (500/ea for manually-saved and automatic/data-logged records) |
Communications |
USB 2.0 (mini-B), IrDA |
Approvals |
CE mark, EN 50379-2 |
Warranty |
2 years (including sensors) |
[1] Depending upon combustion equation setting (North American or Siegert) – see manual for details
[2] For standard 12 in. probe, P/N 0024-3004